mitä kaikkea tästä voipi päätellä?
Marker,Group A:, Not Running,,,,Group B:,'001,,,,Group C:,'011
,,,,,,,RPM,Inj. Quantity,Voltage,Temperature,,RPM,Absolute Pres.,Absolute Pres.,Duty Cycle
,TIME,,,,,TIME,,,,,TIME,,,,
Marker,STAMP,,,,,STAMP, /min, mg/str, V,°C,STAMP, /min, mbar, mbar, %
,,,,,,0.79,861,2.0,1.260,77.4,0.39,861,928.2,1009.8,91.2
,,,,,,1.57,861,2.0,1.300,77.4,1.17,861,928.2,1009.8,91.2
,,,,,,2.37,798,15.4,1.880,77.4,1.97,861,928.2,1009.8,91.2
,,,,,,3.17,966,18.0,1.960,77.4,2.77,1029,1152.6,1020.0,74.5
,,,,,,3.97,1512,24.6,2.300,77.4,3.57,1134,1224.0,1020.0,57.8
,,,,,,4.77,2373,26.2,2.740,77.4,4.37,1932,1856.4,1081.2,34.7
,,,,,,5.57,3318,26.6,3.100,77.4,5.17,2835,1836.0,1305.6,35.5
,,,,,,6.37,4095,0.0,1.480,77.4,5.97,3780,1795.2,1468.8,35.1
,,,,,,7.17,2415,19.8,2.200,77.4,6.77,3318,1081.2,1305.6,62.6
,,,,,,7.97,2688,26.0,2.840,76.5,7.57,2520,1836.0,1285.2,35.1
,,,,,,8.77,3024,26.4,3.020,76.5,8.37,2877,1825.8,1417.8,35.1
,,,,,,9.57,3360,26.6,3.100,76.5,9.17,3192,1825.8,1468.8,34.7
,,,,,,10.37,3675,26.4,3.200,76.5,9.97,3507,1805.4,1468.8,34.7
,,,,,,11.17,3948,25.8,3.240,76.5,10.77,3801,1785.0,1468.8,34.7
,,,,,,11.97,3318,0.0,0.800,75.6,11.57,4011,1519.8,1448.4,36.3
,,,,,,12.77,2562,26.0,2.680,75.6,12.37,2436,1428.0,1224.0,65.7
,,,,,,13.57,2667,26.0,2.820,75.6,13.17,2604,1836.0,1377.0,35.1
,,,,,,14.37,2793,26.0,2.840,75.6,13.97,2730,1836.0,1438.2,34.7
,,,,,,15.17,2898,26.2,2.900,75.6,14.77,2856,1825.8,1448.4,34.7
,,,,,,15.97,3003,26.2,2.960,75.6,15.57,2961,1825.8,1458.6,34.7
,,,,,,16.77,3108,26.4,3.020,75.6,16.37,3045,1825.8,1468.8,34.7
,,,,,,17.57,3213,26.4,3.100,75.6,17.17,3150,1815.6,1458.6,34.7
,,,,,,18.37,3297,26.6,3.060,75.6,17.97,3255,1815.6,1458.6,34.7
,,,,,,19.17,3402,26.4,3.040,75.6,18.77,3339,1805.4,1468.8,34.7
,,,,,,19.96,3486,26.6,3.080,75.6,19.57,3423,1805.4,1479.0,34.7
,,,,,,20.76,3570,26.4,3.180,75.6,20.38,3528,1815.6,1479.0,34.7
,,,,,,21.57,3654,26.4,3.180,75.6,21.16,3612,1805.4,1468.8,34.7
,,,,,,22.36,3759,26.4,3.220,75.6,21.97,3696,1795.2,1468.8,34.7
,,,,,,23.16,3864,26.2,3.260,76.5,22.76,3801,1785.0,1458.6,34.7
,,,,,,23.96,3822,0.0,1.080,76.5,23.56,3885,1764.6,1458.6,34.7
,,,,,,24.76,2373,0.0,0.800,76.5,24.36,3045,1071.0,1295.4,63.4
,,,,,,25.56,1323,0.0,0.800,76.5,25.16,1806,989.4,1162.8,82.5
,,,,,,26.35,1323,0.0,0.800,76.5,25.96,966,928.2,1081.2,91.2
,,,,,,27.16,1722,0.0,0.800,76.5,26.75,1785,989.4,1040.4,91.2
,,,,,,27.96,1659,0.0,0.800,76.5,27.56,1680,979.2,1040.4,91.6
,,,,,,28.76,1617,0.0,0.800,76.5,28.36,1638,979.2,1050.6,91.2
,,,,,,29.60,1575,0.0,0.800,77.4,29.18,1596,969.0,1040.4,91.2
tämä on logattu paikaltaan lähtien vedätetty n. 4krpm asti 3. vaihteelle.
passatin logien tulkintaa
Valvoja: ffp jäsenet
jep, ahto on tiedossa, mulla on pakopaineohjattuna vnt, vaatii vähä kireempää jousta. en oo viittiny vaan ennemmin kiristää ku herjaa ilmamassamittarin vikaa, aattelin etten ennen ala kauheesti urheileen ennenku ns. peruskunto on ok.
sitä ajan tällä takaa että näkee tuon tilanteen mitä siellä tapahtuu, että onko jotain muuta korjailtavaa. ku itte en vielä noista loggauksista käsitä oikeen mitään.
pystykö noita arvoja säätämään vcds:llä? eli suoraan kysyttynä pystyykö tolla ohjelmalla antamaan lisää syöttöä tolle koneelle. paljonko vakio map sietää ahtoa?
sitä ajan tällä takaa että näkee tuon tilanteen mitä siellä tapahtuu, että onko jotain muuta korjailtavaa. ku itte en vielä noista loggauksista käsitä oikeen mitään.
pystykö noita arvoja säätämään vcds:llä? eli suoraan kysyttynä pystyykö tolla ohjelmalla antamaan lisää syöttöä tolle koneelle. paljonko vakio map sietää ahtoa?